| PFS Series PVC Flow Sensors |
|
BFM Series Flow Meters |
|
BHM Series Hydrometers |
|

|
|

|
|
 |
Two-wire Compatible Smart Flow Sensors
Flow Sensors from Baseline are the industry's first two-wire compatible smart flow devices. Since all Baseline two-wire devices have full bi-directional communication, Baseline flow sensors come pre-configured with proper K & Offset values. Also, there is no need to run additional wires to your controller - you can connect all Baseline flow sensors directly to the two-wire path or two-wire port on the controller. Now flow management is easier than ever!
Baseline offers the industry's most comprehensive combination of flow meters, flow sensors, and advanced flow management features. All of Baseline's flow sensors and flow meters ship two-wire Ready - making installation a snap. Baseline's Hydrometer line, in partnership with Netafim and Arad, is the easiest to use and most accurate flow meter and master valve combination in the industry. Baseline also offers industry leading PVC flow sensors - the industry's most accurate flow sensors in low flow conditions. All of Baseline's flow sensors and meters come two-wire ready and are compatible with all Baseline controllers.
BHM Hydrometers - Combination Flow Meters and Master Valves
Baseline is proud to partner with Netafim and Arad on industry leading metal-bodied Hydrometers. All Baseline Hydrometers come with a high-frequency output for maximum real-time accuracy, a human readible register with a total gallons used odometer, and are pre-wired and pre-configured for use with all Baseline two-wire and conventional wire controllers.

BL-BHM150 - Normally Closed Master Valve and Flow Meter Combination
Benefits and Features:
- Available in sizes from 1.5" to 4.0"
- No straight pipe requirement - fit into standard valve boxes
- High precision double chamber hydraulic valve - fast actuating, no springs required
- Hermetically sealed register with high frequency output
- Low head loss
- Cast iron, epoxy coated metal body
- Pre-wired and pre-configured for full compatibility with all Baseline controllers - fewer wires, fewer connectors
- Connects directly to two-wire path, or to two-wire expansion port on conventional controllers
Normally Closed Product Configurations
- BL-BHM150 - 1.5" Male Threaded
- BL-BHM200 - 2.0" Female Threaded
- BL-BHM300 - 3.0" Flange
- BL-BHM400 - 4.0" Flange
Normally Open Product Configurations
- BL-BHM150-NO - 1.5" Male Threaded, Normally Open
- BL-BHM200-NO - 2.0" Female Threaded, Normally Open
- BL-BHM300-NO - 3.0" Flange, Normally Open
- BL-BHM400-NO - 4.0" Flange, Normally Open
Pressure Regulation
Baseline also offers pressure regulation for all BHM Hydrometers as an option. The pressure regulation kit can be added to any Baseline BHM Hydrometer at the factory, or can be installed in the field.
- BL-BHM-PRMEL - Pressure regulation kit for all BL-BHM Hydrometers
Click here for Specifications and CAD drawings for Baseline BHM Hydrometers.
BFM Flow Meters
Baseline extends its flow meter lineup with Netafim's residential and small commercial class flow meters ranging in size from 3/4" to 1.5". Like the Baseline Hydrometers, these brass flow meters are extremely high accuracy, with high frequency outputs for real-time performance, include a human readible register with a total gallons used odometer, and are pre-wired and pre-congifured for use with all Baseline two-wire and conventional wire controllers.
Bronze Flow Meter Configurations
- BL-BFM075 - 3/4" Male Threaded
- BL-BFM100 - 1.0" Male Threaded
- BL-BFM150 - 1.5" Male Threaded
Click here for Specifications and CAD drawings for Baseline BFM Flow Meters.
PFS PVC Tee Flow Sensors
Baseline's PFS PVC Tee Flow Sensors offer industry leading low-flow accuracy, and accuracy across a large range for flows. Baseline's low flow accuracy is better than competitive sensors due to several factors:
- Unique low drag and lightweight HDPE (High Density Polyethylene) impeller design with Tungsten Carbide shaft
- Engineered Tee cavity - all Baseline sensors feature custom molded PVC tee cavities specifically designed to insure smooth flow and highly accurate performance even at very low flow rates.
- Engineered impeller placement - custom molded PVC tees allow very careful sub-millimeter control over the impeller placement in relation to pipe flow.
All of Baslines PVC flow sensors come two-wire ready and can be connected directly to the two-wire path, or to the two-wire expansion port on any Baseline controller.
PVC Tee Flow Sensor Configurations
- BL-PFS100 - 1.0" Schedule 40 PVC Tee Flow Sensor
- BL-PFS150 - 1.5" Schedule 40 PVC Tee Flow Sensor
- BL-PFS200 - 2.0" Schedule 40 PVC Tee Flow Sensor
- BL-PFS300 - 3.0" Schedule 40 PVC Tee Flow Sensor (available early 2010)
- BL-PFS400 - 4.0" Schedule 40 PVC Tee Flow Sensor (available early 2010)
Click here for Specifications and CAD drawings for Baseline PFS Flow Sensors
Pulse Per Gallon Table for all Baseline Flow Meters and Sensors
Baseline Part Number
|
Pulse per Gallon (ppg)
|
K and Offset |
Suggested Operating Range (gpm) |
| BL-BHM150 |
188.68 |
0.318, 0 |
1.8 - 55 gpm |
| BL-BHM150-NO |
188.68 |
0.318, 0 |
1.8 - 55 gpm |
| BL-BHM200 |
117.65 |
0.51, 0 |
5.3 - 95 gpm |
| BL-BHM200-NO |
117.65 |
0.51, 0 |
5.3 - 95 gpm |
| BL-BHM300 |
48.78 |
1.23, 0 |
14 - 220 gpm |
| BL-BHM300-NO |
48.78 |
1.23, 0 |
14 - 220 gpm |
| BL-BHM400 |
5.75 |
10.434, 0 |
21 - 380 gpm |
| BL-BHM400-NO |
5.75 |
10.434, 0 |
21 - 380 gpm |
| BL-BFM075 |
666.67 |
0.09, 0 |
0.2 - 11 gpm |
| BL-BFM100 |
476.19 |
0.126, 0 |
0.3 - 15.4 gpm |
| BL-BFM150 |
135.14 |
0.444, 0 |
0.9 - 44 gpm |
| BL-PFS150 |
92.307 |
0.650, 0.750 |
1.5 - 100 gpm
|
|
|
|
|
|